Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tab. 3 :
Technical
specifications
EN
46

Technical data

Feature
Voltage supply V
B
Voltage drop between supply voltage
and output voltage
Rated current consumption
Maximum output current for locks
Maximum release delay after pressing of
the Emergency Open button
· DIN EN 13637
· with local control
· with central control
· without CE certification (EU export)
· with local control
· with central control
Application Site
Protection rating
Operating temperature
Test certificate in accordance with
Characteristic
in accordance with
DIN EN 60950–1 SELV
24 V (±15 %)
approx. 1 V DC
100 mA (without locking element)
600 mA
t
1 s . . . 15 s
1
t
1 s . . . 180 s
2
t
1 s . . . 120 s
1
t
1 s . . . 300 s
2
for use in indoor areas
IP30 (when completely mounted)
–10 °C – +55 °C
EltVTR
DIN EN 13837:2015
Technical data

Publicité

Chapitres

Table des Matières
loading

Table des Matières