RE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be
flexible during the movement and must move without frictions.
Before the installation of KING, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in
Fig. 1.
Gate features must be uniformed with the standards and laws in
force. The gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical
stops are not safe enough.
E
MERGENCY RELEASE
To move the gate manually it is necessary to release the operator
inserting the special key and turning it 3 times in the anti-clockwise
sense (Fig. 3).
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for
the operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390N for
doors/gates for commercial and industrial sites ( values indicated in
5.3.5 of the EN 12453 norm).
F
IXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the leaf gate it is necessary to respect
the measures.
In case an iron pillar is available, weld the bracket straight to it.
In case you need to fix the bracket onto a concrete pillar, use the fixing
plate as shown in picture 4, to be fastened with 4 Fischer screws of Ø
8 mm.
In the case you have a wall parallel with the open gate, you must
provide a niche in which to place the operator.
F
IXING THE ACTUATOR ATTACHMENT TO THE GATE
Weld the base at the right height (Fig. 6, 7).
Fix the KING and try several times to open and to close the gate,
controlling that the screwcover does not touch the moving gate.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
with manned operation
A
with visible impulses
C or E
(e.g. sensor)
with not visible impulses
C or E
(e.g. remote controldevice)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety edges, like code ACG3010 and/or other safety devices to keep thrust
force within the limits of EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
4
5
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
non possibile
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
3
6