ELECTRIC CONNECTIONS
M1
*
1 -> S
2 -> +
3 -> GND
EXTERNAL SIGHT
*
ENCODER CONNECTOR
1
=> 1-2-3 are the plugs of the connector where you have to insert one side of the 3 WIRES (DO NOT CONNECT
3
=> S, +, GND are the plugs of the control board where you have to insert the other side of the 3 WIRES. The
2
INTERNAL SIGHT
WIRING ENCODER
CONNECTOR
1 -> V
2 -> W
3 -> U
->
Where:
THE SHIELD)
SHIELD must be connected to the EARTH from the power supply (not to GND).
WARNING!
The length of connection cables from the motors to the control panel unit must not
exceed 15 m.
The wire section of the motor power supply must be 1.5 mm
accessories must be 0,75 mm
As for the encorder it is very important to use a shielded wire with a section of 0,75
mm
(Ex: type ÖLFLEX-110 CH - code ACG2133).
2
It is compulsory to use shielded cable for the encoder in order to guarantee the
correct operation of the control board.
To ensure the correct functioning of the installation it is advisable to wire encoder
and motor with separate cables.
M2
.
2
electric board KS2
, whilst that of the
2
G G
B B