3.
Unzip bag and shake out debris.

Maintenance

Clogging

If the unit becomes clogged with debris, the
obstruction can usually be cleared by turning the unit
off and then promptly compressing the bag while it is
still inflated, thereby forcing air back out through the
vacuum tubes. This reverse airflow is usually
sufficient to dislodge most obstructions.
If the restriction cannot be cleared by compressing the
bag, then proceed with caution as follows:
1.
Turn off and unplug unit.
2.
Remove vacuum tube.
3.
Using a small stick or rod, carefully reach into
impeller opening and clear out debris.

Bag Cleaning

Debris should not be stored in vacuum bag. Bag
should be emptied after each use for more efficient
operation. After about three uses, bag should be
thoroughly cleaned. Turn bag inside out and shake
out dust and excess debris vigorously. Once a year,
wash the bag by hand in soapy water.
GB–8
POTENTIAL HAZARD
Under normal usage, the bag material is
subject to deterioration and wear.
WHAT CAN HAPPEN
Small objects could pass through a worn or
damaged bag and be thrown in direction of
operator or bystanders and cause serious
personal injury.
HOW TO AVOID THE HAZARD
Check bag frequently for wear or
deterioration. If bag is damaged, replace it
with a genuine TORO part.
Impeller Replacement (Fig. 19)
If a loss of performance is detected while operating
blower, unplug unit, remove inlet cover, and check
impeller blades for wear. If blades are severely worn,
see your Authorized TORO Service Dealer for a new
impeller.
Servicing Double-insulated
Appliance
In a double-insulated appliance, two systems of
insulation are provided instead of grounding. No
grounding means is provided on a double-insulated
appliance, nor should a means for grounding be added
to the appliance. Servicing a double-insulated
appliance requires extreme care and knowledge of the
system, and should be done only by qualified service
personnel. Replacement parts for a double-insulated
appliance must be identical to the parts they replace.
A double-insulated appliance is marked with the
words "DOUBLE INSULATION" or "DOUBLE
INSULATED." The symbol (square within a square)
may also be marked on the appliance.