Instruction manual BDC-23-230V-P_ BDC-23-110V-P
Absolute filter assembly or
replacement
Do not use the absolute filter again after having
removed it from the vacuum cleaner.
1.
Vacuuming unit
2.
Closing band
3.
Filter shaker stop
4.
Filter shaker knob
5.
Washer
6.
Ferrule
7.
Absolute filter
8.
Seal
9.
Disc
10.
Nut
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Assembly
1.
Release the stop (3) and unscrew the filter shaker knob
(4), release the closing band (2) and remove the head
(1).
2.
Unscrew the nut from the ferrule under the head (1),
insert the washer (5), screw the ferrule (6), insert the
filter (7), the gasket (8) and the disc (9), screw the
nut (10), fit the head back in position and fix with the
closing band (2), screw the knob (4) and lock it with
I
the stop (3).
Replacement
US
1.
Proceed as indicated in step 1 of the assembling
procedure.
2.
Unscrew the nut (10), remove the disc (9) and the
gasket (8).
3.
Replace the filter (7) and proceed in the reverse order
to reassemble the head.
To dispose of the filter put it in a sealed plastic bag, close it
hermetically and dispose of it in accordance with the laws in
force.
WARNING!
Figure 8
WARNING!
Tightness inspection
Hoses check
Figure 9
Make sure the connecting hoses (1) are in a good condition
and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle plate
inside the filtering chamber.
Scrape inlet (2) from the outside and remove the deposited
waste as indicated in the figure.
Wiring diagrams
Figure 10
www.blastrac.com ‒ info@blastrac.com