ENGLISH
Washbasin with register
knee
hot and cold water knob
Ref. 061002
Contents
- Sheathing for washbasin with feeder plug.
461004 - Turning tap 160x180x1 (50mm nut).
461206 - H-H 1/2" (550mm) fl exible hose with stainless steel mesh.
460404 - 1/2" M-M timer button.
461604 - 1/2" M-H-M non-return mixer.
461802 - 1/2" M-H 90° knee.
454202 - 2 1/2" valve with trough for 500mm sink.
409822 - Plastic nylon Fisher 6x30mm peg.
421038 - Plate thread bolt 22x4,8mm. DIN 7981 A2.
Assembly
Check the contents.
Avoid dirt in pipes and in the area before assembly.
If the plumbing is new, let the water fl ow.
When assembling, it is advisable to use special gloves not to get cuts on hands.
Use teffl on to seal connexions.
Pull out front door and remove the plastics from doors and washbasin.
Connet both knees for each of the buttons output. To seal the connection use teffl on
·
Fig. 1
Connect the output of the mixer T to the input knee of the button. (See arrow at the
bottom of the button) ·
Fig. 1
Connect the mixed water fl ex hose that goes with the output knee (see point of button
arrow to check the input direction ) Use Teffl on to seal the connection ·
Introduce the pipe in the upper orifi ce and fi x it the attached bolts ·
Connect the free end of the mixed water fl ex hose to the output.
English
FRICOSMOS
Introduce the push button in the orifi ce from the inside of the case and fi x it with its
bolt from the outside.
Assemble the discharge valve ·
Fix the washbasin on the wall ·
You can now connect the water input and the discharge to the washbasin.
Adjust the desired temperature by turning the non-return mixing crown.
Handling
To open the water keep the button pressed with the knee or thigh.
To stop the water release the button.
Temperature can be adjusted with the non-return mixer handle.
Maintenance
Use only water and neutral soap when cleaning.
Wipe with a soft cloth.
Rinse with plenty of water.
Dry with a soft cloth.
Do not use acids or strong detergents and do not rub with a scourer or spatula.
Safety
When cleaning, be extra careful with corners.
Other hazards have not been observed.
Available spares
461004 - Turning tap 160x180x1 (50mm nut).
461206 - H-H 1/2" (550mm) fl exible hose with stainless steel mesh.
460404 - 1/2" M-M timer button.
461604 - 1/2" M-H-M non-return mixer.
Fig. 1
461802 - 1/2" M-H-M 90° knee.
454202 - 2 1/2" valve with trough for 500mm sink.
Fig. 2
Fig. 3
Fig. 4
All sizes are described in mms.