Kuppersbusch K 3 Serie Mode D'emploi page 32

Masquer les pouces Voir aussi pour K 3 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use
a medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L1 to the terminals 1
and the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
32
Protection calibre
25 A *
16 A *

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ke8330.0sr

Table des Matières