AC-D 24/2MC EASY - AC-D 50/2MC EASY
figure 1
If an extension lead is required, use an approved
and compatible lead rated for this appliance.
Follow all the instruction supplied with the ex-
tension lead.
*Double insulated: This product requires
no earth connection as supplementary in-
sulation is applied to the basic insulation to
protect against electric shock in the event of
failure of the basic insulation.
pRODUCT SpECIFICATIONS
INTENDED USE
This machine is intended for machinery, spraying
and decoration, automatic control systems and
other related fields, where compressed air is re-
quired. Its main characteristics are: compact con-
struction, light weight, easy operation, high safety
and low noise.
TECHNICAL DATA
Article number
Model
Input rated
V
voltage
Hz
Frequency
Output rated
Hp
power
Motor Poles
P
Rated Speed
min
-1
Cut off
PSI
pressure
Cut in
PSI
pressure
Tank Capacity
L
Air displace-
L /min
ment
Weight
kg
Sound emission values determined according to
EN ISO 3744:1995
Typically the A-weighted noise levels of the product are:
Sound
pressure
dB(A)
level
Sound power
dB(A)
level
Uncertainty K
dB
45 897
45 898
AC-D 24/2MC
AC-D 50/2MC
EASY
EASY
230
50
2
2
2
2
2.850
2.850
115
70
24
50
222
25
32
76,2
96,2
3
IDENTIFICATION
1. Main compressor & electric motor
2. Pressure switch
3. Outlet valve
4. Regulating valve
5. Pressure gauge
6. One-way valve
7. Drain cock
8. Wheel
9. Air tank
10. Safety valve
11. Fan cover
BEFORE OpERATION
f Place the compressor in a clean, dry and well-ven-
tilated environment.
f Keep the voltage variation between ±5% of the
rated value.
f Keep the oil levels in the red circle leveler.
f It is recommended to use SAE30 compressor oil
f Open the outlet valve, set the knob of the pres-
sure switch in position "ON" (Fig.2) and let the
compressor run for 10 minutes with no load, in or-
der to ensure the lubrication of the moving parts
before regular service.
figure 2
OpERATION AND ADJUSTMENT
f The compressor is controlled by the pressure
switch, when it is working under normal condi-
tions. It stops automatically as pressure increases
to the max and restarts as pressure decreases to
the min. The rated pressure has been adjusted
when produced. As soon as the motor is switched
off, the compressed air in the discharge pipe
should be released through the release valve un-
der the switch. This condition is necessary in or-
der to restart, or else the motor will be damaged.
The rated pressure can be adjusted by turning the
bolt of the switch.
f The output pressure of compressed air can be ad-
justed by the regulating valve. Pull up the knob
of regulation valve and turn it clockwise or coun-
terclockwise, in order to increase or decrease the
pressure.
f The compressor, while operating, can be stopped
only by setting the pressure switch in position "OFF".
CAUTIONS
f Remove the cover and put on the breath pipe and
the air filter before the compressor runs.
f Never unscrew any connecting part when the
tank is in pressure condition.
f Never disassemble any electrical part before dis-
connecting the plug.
f Never adjust the safety valve incautiously.
f Never use the compressor in a location where
voltage is too low or too high.
English |
7
ON/OFF
www.ffgroup-tools.com