INSTALLATION
TRANSITION HEIGHTS:
TRANSITION HEIGHTS:
Dual Blower (WM2L = 600 CFM): no transition - 8" round duct will connect directly to the
EN
blower outlets, 9" below top edge of the hood.
Single and Dual Blower (WM1L + WM2L = 900 CFM): 6" round duct will connect directly
to the single blower outlet, 8" round will connect directly to the dual blower outlet.
The outlets are 9" below top of hood. If using the optional multi-blower transition
(AKVT6810, sold seperately), a 10" round duct connects to it 8-1/2" above top of hood.
Two Dual Blowers (Two WM2Ls = 1200 CFM): 8" round duct will connect directly to each
dual blower outlet. The outlets are 9" below the top of hood. If using the optional multi-
blower transition (AKVT8812, sold seperately), a 12" round duct connects to it 7-1/2"
above top of hood.
CONNECTION DIAGRAMS
CONNECTION DIAGRAMS
8-1/2"
[21.6 cm]
18"
[45.7 cm]
Optional AKVT6810 transition
12
©2020 Hestan Commercial Corporation
(CONT.)
Connection diagram (42", 48" widths)
5-1/2"
7-5/16"
(Wall
[14 cm]
[18.6 cm]
Side)
Electrical (2)
WM2L Dual + WM1L Single Blower (900 CFM)
10"
[25.5 cm]
piece installed
Connection Diagram (30-36" width)
5-1/2"
[14 cm]
(Wall Side)
1-3/4"
[4.4 cm]
Electrical
Motor
Cooling
Vent (2)
8" [20.3 cm] Round
WM2L Dual Blower (600 CFM )
7-5/16"
[18.6 cm]
Motor
5-1/4"
Cooling
[13.3 cm]
Vent (3)
Centerline
8" Round
of hood
For 900 and 1200 CFM hoods, a transition
(AKVT6810 or AKVT8812) may be installed.
Its outlet will be located in the exact center of
the duct cover (left to right & front to rear).
(Front View)
5-1/4"
[13.3 cm]
Centerline
of Hood
(Top View)
1-7/8"
[4.8 cm]
1-3/4"
[4.4 cm]
6" [15.2 cm]
Round
(Top View)
Duct cover
(top of hood)
10" Dia. or 12" Dia.
transition centered
in cover