3. After setting the value of StEP, press both keys
simultaneously; the following message is displayed:
4. Use the right key to select YES or no
⇑
5. If YES is selected, press both keys simultaneously
to end the programming. All parameters set are
saved.
⇑
⇑
6. The device is ready for operation.
4.2.2.1 The
MAn Operating Mode
1. If YES was selected for
can show a value different from the value of the
output setpoint.
2.The SPecial disPlay function
A
SPecial disPlay Function in
, the display
to
to
–
The function SPecial.decimalPoint
allows defining the number of decimal places
(only for the values appearing on the display).
–
display.Low allows defining the min-
imum value to be displayed. This value corre-
sponds to the value ou.Lo used for the output set-
point.
–
display.High allows defining the
maximum value to be displayed. This value corre-
sponds to the value ou.Hi used for the output set-
point.
Example:
The display must show 10 (kg) while the setpoint
output must be 2 V (lower limit value); the display
7
D
6
A
8 V
2 V
10 kg
must show 40 (kg) while the setpoint output must
be 8 V (upper limit value).
3. Press both keys to resume programming at point
4.2.2 (1), SiGn see
⇑
⇑
Summary:
Display
Output value
When programming, the values for the display and
for the output setpoint are linked internally together.
Note:
When the SPecial display function is activated, the
increment relates to the value scaled in the MAn
operating mode.
40 kg
A
in the flow chart
7