SiGnal allows selecting the setpoint
output in volts or mA. Press both keys to switch
over from SiGn to ou.Lo and ou.HI.
output.Low allows defining the lowest
value.
output.High allows defining the highest
value.
During operation, it is not possible to define a value
lower than the ou.Lo value or higher than the ou.Hi
value. The default value for ou.Lo is 0 V or 0 mA.
The default value for ou.Hi is 12 V or 24 mA.
2. After setting the value of ou.Hi, press both keys;
the following message is displayed:
3. Use the right key to select YES or no.
4. If YES is selected, press both keys simultaneously
to end the programming. The new values are
saved.
5. The device is ready for operation.
6. If, during operation, the operator switches to the
programming mode and alters the parameters
ou.Lo or ou.Hi take into account the following
when exiting the programming mode:
If the value of parameter ou.Lo was altered, the
output of the device will automatically be set to the
value of parameter ou.Lo when it will be set back
to operation.
If the value of parameter ou.Hi was altered, the
output of the device will automatically be set to the
value of parameter ou.Lo when it will be set back
to operation.
6

4.2.2 The MAn Operating Mode

1. The following parameters can be programmed for
the MAn mode:
2. Functions
Special display function, see
4.2.2.1
SiGnal allows selecting the setpoint
output in volts or mA.
output.Low allows defining the low-
est output value.
output.High allows defining the
highest output value.
StEP allows defining the increment.
During operation, the setpoint output will increase
by this value when the right key is pressed. The set-
point output will decrease by this value when the left
key is pressed.
During operation, it is not possible to define a value
lower than the ou.Lo value or higher than the ou.Hi
value.
Note
If, during operation, the operator switches to the pro-
gramming mode and alters the value of ou.Lo, ou.Hi,
di.Lo or di.Hi the parameter StEP will be reset to
zero and the output value will be reset to ou.Lo or
di.Lo.