Rel1.1; Rel2.1; 24V; Elan Gnd - hager RTN300X Manuel

Module porte ip
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RTN300X · RTN301X
Introduction / Connection and power supply
Table of contents
Introduction
Network connection and power supply
Connecting the call button, lighting, relays
LED status displays
Extension port for display call, keypad
Safety instructions
The installation and assembly of electrical equipment may only be carried out by an electrician in compliance with applicable in-
stallation standards, directives, regulations, safety and accident ordinances for the local country. When working on systems with a
230 V~ power connection, the safety requirements of DIN VDE 0100 must be met. Failure to comply with the instructions can cause
damage to the device, fire or other dangers. These instructions are a component of the product and must remain with the end cus-
tomer.
System information and intended use
This device is a product of the IP door intercom system and can only be used within the defined installation scenarios. Detailed
technical knowledge from IP training is assumed in order to understand them. The function of the device depends on its configura-
tion. You can find more information about the specific functional scope in the corresponding application descriptions in the product
database.
Network connection and power supply
PE
0V
+UB

REL1.1

REL1.2

REL2.1

REL2.2

+24V

ELAN
GND
NET
NET
WORK
WORK
OUTPUT
INPUT
IP door speaker module via PoE switch
The INPUT port of the IP door speaker module is con-
nected through a network cable (CAT5 or better) to a
PoE switch (IEEE 802.3af-compliant).
Attention: The module may not be connected directly
through a connector crimped onto a cable. Crimp a
socket and use a short, flexible network cable between
the two.
12
12
12
13
13
14

S3B

GND
+5V

LEDB

Z1
Z2
Z3
Z4
GND
IP door speaker module with 28VDC power supply
Connect terminals 0V and +UB of the IP door speaker module to a
28VDC power supply (RED013X). The INPUT port is connected via a net-
work cable (CAT5 or better) to an Ethernet switch.
Attention: An RTN500X IP camera module connected on the OUTPUT
port is also supplied with power. However, this is not a standard PoE
power supply. Other (PoE) devices can be connected through this port
for network services, but generally cannot receive power.
Subject to technical changes
Factory settings
Reset to factory settings
Installation concepts and configuration
Quick start configuration with RTD110X
Expert configuration
PE
0V
+UB
REL1.1
REL1.2
REL2.1
REL2.2
+24V
ELAN
GND
+
-
OUTPUT
L
N
14
14
15
16 - 17
18 - 21
S3B
GND
+5V
LEDB
Z1
Z2
Z3
Z4
GND
NET
NET
WORK
WORK
INPUT
www.hager.com

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rtn301x

Table des Matières