9. TROUBLESHOOTING
Error
After pressing the ON/OFF button,
there is no LCD display.
No AC output after pressing the
AC switch, LCD display is normal
USB without output
12V or USB DC consume energy
quickly
Unit is not fully charged by solar
charging
10. SUPPLY
• BPS1000 or BPS1500 Powerstation
• Mains adapter
• Mains cable
• DC output cable 1+4; 4 in 1 cable
• Car charger cable (cigarette lighter)
• Solar cable plug (M4)
• USB adapter
• User manual
11. TRANSPORTATION
Since a lithium battery is permanently installed in the Berger Powerstation BPS1000 and
BPS1500, the regulations for lithium batteries also apply. When transporting lithium batteries,
all national and international regulations and laws must always be observed. Transport may
only take place in the original packaging or packaging corresponding to this. Never transport
damaged LiFePO4 batteries; this may only be done in prescribed containers. LiFePO4 batteries
installed in devices are classified according to UN3481, Class 9 during transport.
26
Reason
The internal lithium bat-
tery is not charged
Over temperature
Overload
Under voltage
USB output/display
switch is off
AC switch is on; standby
current is too high
The solar panel is not
suitable and/or the solar
radiation is too low
Solution
Charging
Disconnect the load
Check the power con-
sumption of the connected
consumer, reduce power or
switch off
Charging
Press the ON/OFF switch to
switch on.
Switching off the AC switch
during DC output
Select a suitable solar
module and ensure that the
charging voltage is higher
than 13V.