8. SHUTDOWN CONDITIONS
Shut-down condition
Inverter
Overtemperature
Overload
AC output circuit
Note: If the AC output has switched off due to one of the above conditions, disconnect the
load, switch off the AC switch and switch it on again.
DC controller
USB Overcurrent
12V DC overcurrent protection
at the output
Solar charging, protection,
voltage cut-off
Battery
Overcharge protection for one
cell; Voltage protection
Deep discharge protection
Batterypack Overtemperature
protection
Short circuit protection
Overcurrent protection for the
battery pack
Specification
Inverter tempera-
ture
≥ 65°C
> 1000 (PS 1000)
> 1500 (PS 1500)
3
15
29,2 – 29,7
4,2 per cell
2,8 per cell
≥ 65
Ja
120 – 180
Unit
Comment
°C
No AC output, wait
until temperature
drops
W
No AC output, discon-
nect load and restart
W
No AC output, discon-
nect load and restart
A
No DC output
A
No DC output
V
Disconnects the charge
after reaching the
voltage
V
Separates the charge
V
Output will be swit-
ched off
°C
Input and output are
switched off
Output is switched off
after short circuit
A
Output is switched off
after overcurrent
GB
25