The following figures are a guide to the best settings:
Special feature of the SKP 100 G2 plug-on transmitter:
In order to be able to use highly sensitive directional condenser microphones
with separate powering, the SKP 100 G2 plug-on transmitter offers a sensiti-
vity range extended by 20 dB. With the transmitter plugged onto a directio-
nal condenser microphone, the following figures are a guide to the best set-
tings:

Adjusting the audio output level (receivers only)

AF OUT
Via the
The level can be adjusted in eight steps. Adapt the level of the audio output
(AF OUT) to the input of the connected unit. The following figures are a guide
to the best settings:

Adjusting the squelch threshold (receivers only)

SQELCH
The receiver is equipped with a squelch that can be adjusted via the "SQELCH"
menu. The squelch eliminates annoying noise when the transmitter is
switched off. It also suppresses sudden noise when there is no longer
sufficient transmitter power received by the receiver.
There are three possible squelch settings:
Selecting the setting "LO" reduces the squelch threshold, selecting the set-
ting "HI" increases the squelch threshold. Adjust the squelch threshold – with
the transmitter switched off – to the lowest possible setting that suppresses
hissing noise.
Loud music/vocals:
–30 to –20 dB
Presentations:
–20 to –10 dB
Interviews:
–10 to 0 dB
Musical instruments:
– electric guitars with single coil pickups:
– electric guitars with humbucker pickups:
– guitars with active electronics
(active pickups, active EQs, piezo pickups):
Loud music/vocals: –50 to –40 dB
Presentations:
–40 to –30 dB
Interviews:
–30 to –20 dB
"AF
OUT" menu, you can adjust the audio output level of the receivers.
Line level input:
Microphone level input:
Note:
Before adjusting the squelch threshold to a different setting, set the
volume on a connected amplifier to the minimum.
LO
= low
MID
= middle
HI
= high
–10 to 0 dB
–20 to –10 dB
–30 to –20 dB
EM 100 G2
EK 100 G2
0 bis +18 dB
0 bis +12 dB
–24 bis –6 dB
–30 bis –6 dB