13. Install the rear access cover with the vent tube coming
out the upper left bushing, the 20' discharge tube com-
ing out the upper right bushing, and the service power
cord out the lower bushing. (See Figure 8). Fasten the
vent tube to the rear of the ice machine with the screws
and "P" clamps provided in the drain pump kit. Fasten
the access cover to the back of the ice machine with
the screws removed in step 6.
14. Run the 20' drain tubing to a suitable drain. The maxi-
mum lift of the drain pump is 8 feet (2.4 meters).
DRAIN PUMP INSTALLATION
When finished with the drain pump installation the ice ma-
chine can be returned to service. Refer to your ice machine
owners guide for turning the ice machine "ON". Be sure the
water to the ice machine is turned on.
"P" clamp
and screws
Vent tube
out upper
left bushing
Service power cord
out lower bushing