Marvel 41013943 Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Remove the leveling leg in the back left corner. See
Figure 7. Insert the drain pump into the rear of the cabi-
net so the tubing connections are positioned as shown.
9. Insert and position the foam shipping block above the
drain pump behind the tubing connections so it rests
between the top of the drain pump and the bottom of
the cabinet.
10. Connect power cord wire connector to the drain pump
wire connector (see Figure 7a), and attach the drain
pump ground wire to the back flange of the cabinet
base where shown in Figure 7. Plug the male plug from
the 18" wire harness into the outlet on the side of the
drain pump.
Drain pump ground wire, fasten to
cabinet back flange, see Figure 7.
Shipping
block
Leveling leg
Attach drain pump
ground wire here
(step 9)
DRAIN PUMP INSTALLATION
11. With the hose clamps from the drain pump kit connect
When replacing tube clamps, do not overtighten which
could damage the tubing. Tighten screws until "snug", then
retighten several minutes later after the material relaxes, to
assure a water tight connection.
12. Re-install the leveling leg to its original position.
18" (45.7 cm)
vent tube
20' (6.1 meters)
discharge tubing
Figure 7
6
the 18" vent tube, the 20' discharge tubing, and the
drain tee to the drain pump as shown in Figures 7 and
7a.
CAUTION
!
Service cord and drain
pump wire connectors
(step 9)
Male plug from 18"
(45.7 cm) wire harness.
Figure 7a
Drain tee

Publicité

Table des Matières
loading

Produits Connexes pour Marvel 41013943

Table des Matières