29 Radio recelver 2
30 Radio recelver 2
TERMINAL BLOCK M6
31 Courtesy light interference-free contact 800W Max
32 Courtesy light interference-free contact 800W Max
TERMINAL BLOCK M5
33 + LED
34 - LED
In order to check the status of the gate a LED can be connected with a 1 KOhm resistor in series. The LED's cathode (short pin)
is to be connected to the negative end (terminal 34), while the resistor can be mounted elther on terminal 33 or 34.
TRIMMER T1 controls the engine voltage between 120 V and 230 V.
This function is automatically operated about 3 seconds after the engines start up and designed to provide the maximum power.
When the open signal is transmitted the terminal board provedes a temporery close pulse to the wings in order to ease the electrical
lock release.
This function can be cut off with the DIP 3 swtich.
TERMINAL BLOCK M4
nd
channel output
nd
channel output
ELECTRICAL LOCK RELEASE
29
CH2
31
Luce cortesia
33
1 K Ω
LED
STATUS LED
ELECTRICAL GEAR
14
30
MAX 1A x 24V
32
1K
34