1
Antenna
2
Antenna groung connection
(it must not touch the wire)
3
Power supply 24Vca
(15 watt max)
4
Power supply 24V ca (15 watt max)
5
Electrical lock power supply 12V ca
6
Electrical lock power supply 12V ca
7
Common
8
Open income (N.A.)
1
2
3
TERMINAL BLOCK M2
19 Blinker interference-free contact
20 Blinker interference-free contact
21 Engine close 2
22 Engine apen 2
23 Engine common 2
24 Engine close 1
25 Engine apen 1
26 Engine common 1
TERMINAL BLOCK M1
4
5
6
7
8
EL
12 Vac
TERMINAL BLOCK M3
27 Power supply 230 V 50/60 Hz
28 Power supply 230 V 50/60 Hz
9
Close income (N.A.)
10 Pedestrian open income (N.A.)
11 STOP income (N.A.)
12 Common
13 Photocell income (N.C.)
14 Income End-of-stroke close (N.C.) Engine 2
15 Income end-of-stroke open (N.C.) Engine 2
16 Common
17 End-of-stroke income close (N.C.) Engine 1
18 End-of-stroke income open (N.C.) Engine 1
9
10
11
12
19
20
21
22
LAMP
M1
27
13
13
14
15
16
23
24
25
M2
28
17
18
26