CPV..-GE-ASI-4E4A-...
3.7 Conversion of the CP valve terminal
The CP valve terminal can be fitted with double-solenoid valves
and/or with single-solenoid valves. If the valve terminal is con-
verted, the new configuration must be set by means of a DIP
switch on the bottom of the sub-base. Instructions on removing
the sub-base can be found in the pneumatics manual.
DIP switch on the bottom of the sub-base
Terminal with 2 double-
solenoid valves
Valve location: valve type
1: Double-solenoid valve
2: Reserve/isol. plate
3: Double-solenoid valve
4: Reserve/isol. plate
9711NH
Terminal with 4
single-solenoid valves
1: Single-solenoid valve
2: Single-solenoid valve
3: Single-solenoid valve
4: Single-solenoid valve
Terminal with 1 double-
solenoid and 2 single-
solenoid valves
1: Double-solenoid valve
2: Reserve/isol. plate
3: Single-solenoid valve
4: Single-solenoid valve
21