UNIK2E
V2
4.2
SIMPLIFIED LEARNING PROCEDURE (also see pages 8-10)
3. Verify the initial settings.
4. Program the remote controls (if needed) with the gate stopped (green LED GC turned on) according
to the following:
d) Press the program button P2/RAD for two seconds: the red LED "RAD" lights up.
e) Press the desired button on each transmitter.
f)
Press the program button P2/RAD to exit the programming mode.
LEARNING START:
1
Position the
gates half
open
1
INITIAL SETTINGS OF THE CONTROL UNIT
DIP N.
Description
DIP STATUS
OFF OFF
OFF
1, 2
CHRADIO
ON
ON
OFF
3
FAST
ON
OFF
4
STRIKE
ON
OFF
5
LAMP
ON
OFF
6
STEP
ON
OFF
7
AUTO
ON
OFF
8
PHTEST
ON
2
Force/speed
Pause time
(FOR)
(PAU)
Reg. from 50 to
Reg. de 0 à
100%
60s
3
OPERATOR MODEL SETTING (pag. 4)
Adjust trimmers if necessary
ATTENTION
A variation of trimmer "FOR" (speed)
requires the repetition of the learning procedure from
RESET (the manoeuvre time changes)
RESET:
2
press and hold
the programming
button P1/SET for
2 seconds
Operation
Button 1 of the TX enabled
ON
Button 2 of the TX enabled
OFF
Button 3 of the TX enabled
ON
Button 4 of the TX enabled
Rapid re-closing disabled
Rapid re-closing enabled
Lock stroke disabled
Lock stroke enabled
Flashing light fixed
Flashing light flashing
OPEN/PAUSE/CLOSE Mode
STEP by STEP mode
Automatic closing disabled
Automatic closing enabled
Safety test disabled
Gate open spy activated
Safety test enabled
Gate open spy deactivated
TRIMMERS
Obstacle sensitivity
(OBS)
Obstacle
intervention time
from 0,1 to 3 sec.
ENGLISH
Yellow LED
flashes
5
Leaves delay
(DEL)
Closing delay
from 0 to 15 sec.
6
ISUNIK2Ev2_EU_10_12.doc
3
Within 5 seconds, press
the programming button
P2/RADIO for 1 second
Yellow LED stays on
4
The two leaves briefly
open
If motors turns in reverse,
invert wires and start
procedure again from
RESET.
The second leaf closes
ATTENTION
If first leaf instead of second leaf
closes, exchange the two motors
and repeat the procedure from
RESET
6
The first leaf closes
The two leaves open until
7
mechanical stop or
electrical limit switches
8
Pause for 1 second
The two leaves close until
9
mechanical stop or
electrical limit switches.
Yellow LED switches off
End of learning