Monacor DAC-199 Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
4 Connection
Connect the enclosed cable according to the follo-
wing list with the alarm center and its plug in the CN3
socket.
The connection 6 is switched via a transistor to
ground for 0.5 seconds if for 9 times a wrong code
number has been entered. With corresponding con-
nection to the alarm center by this an alarm can addi-
tionally be released.
The red and green LEDs of the keypad controller
serve as a state indication of the alarm center and
can be connected in parallel with the indications of
the alarm center, e. g. green LED = alarm center
activated, red LED = alarm. If in the alarm center
there are already series resistors for the red and
green LEDs of the keypad controller, the 1 kΩ series
12
1 red
2 black
3 grey
4 grey
5 orange
6 brown
7 black
8 blue
9 black
10 green
11 white
12 violet
13 yellow
(+) 8-13.8 V
(-) ground
anti-tamper switch (NC)
anti-tamper switch (NC)
not connected
signal if wrong number entered
9 times
red LED negative
red LED positive
green LED negative
green LED positive
NC relay contact
common relay contact
NO relay contact

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

04.1180Dac-29904.1190

Table des Matières