EN
the system in "SYSTEM ACTIVE" MODE ("ON/OFF" and
"manual" keys on).
Whereas, if the pneumatic buttons are active ("manual" key
off), it is not possible to start the pumps and/or blower using the
control keyboard.
The system remains on (with the above described modes)
continuously (P4=0 parameter, "parameters setting menu"
chapter). Press the "ON/OFF" key or the main switch to turn off
the functions.
NOTE: if the pumps and/or blower have been activated via the
control keyboard and then the pneumatic buttons are activated
(by keeping the "manual" key pressed for about 3 seconds),
the devices in operation turn off.
By turning on the whirlpool and/or the blower, the ozoniser (if
present) is turned off, remaining off for a further 15
off, it is automatically started and kept on for 15 minutes after
the last switch-off. This because turning on the system signals
water to keep it clean.
The blower can be turned on simultaneously, or separately,
from the whirlpool pumps. Turning on the blower also turns on
Aromatherapy: a perfumed essence cartridge can be inserted
in the blower, directly in the inlet piping of the blower assembled
on the spa-pack.
UNDERWATER CHROMOTHERAPY FLOODLIGHT
pneumatic button, but it can also be activated/deactivated using
the spa-pack keyboard.
With the system in "SYSTEM ACTIVE" mode and the control
keyboard enabled ("manual" key on), press the "light" key to
If the "manual" key is off (meaning the pneumatic buttons are
active), keep it pressed for about 3 seconds to activate the
control keyboard.
PNEUMATIC BUTTONS
When the buttons are being installed, they are normally
disabled. To enable them (from the spa-pack keyboard), activate
the system using the "ON/OFF" key and keep the "manual" key
pressed for about 3 seconds until it turns off.
If the "manual" key is already off it means that the pneumatic
buttons have already been activated.
NOTE:
When
the
pneumatic
consequently the control keyboard keys are deactivated,
except those for programming/settings, or the ON/OFF key.
W2
W1
The pneumatic buttons allow you to control the following functions:
W1 - Whirlpool (Whirlpool area 1)
W2 - Whirlpool (Whirlpool area 2)
A - Airpool (Blower)
F
WHIRLPOOL
Press the "W1" and/or "W2" pneumatic button to start the
buttons
are
active,
F
A
whirlpool in area W1, W2 or both (attention: during installation,
the buttons may have been connected differently).
W1
W2
To turn off the whirlpool function ("W1" and/or "W2"), before
the pre-set "timeout" duration of 20 minutes, press the
corresponding pneumatic button again.
NOTE: The pre-set "timeout
AIRPOOL
Press the "A" pneumatic button to activate the Airpool: the
corresponding nozzles that supply air bubbles activate.
A
The airpool can be turned on simultaneously, or separately,
from the whirlpool .
To turn the Airpool function off before the pre-set "timeout"
duration of 20 minutes, press the corresponding pneumatic
button again.
NOTE: The pre-set "timeout
Aromatherapy:
perfumed essence that is released with the activation of the
CHROMOTHERAPY FLOODLIGHT
Press the "F" pneumatic button
chromotherapy cycle no. 1; press it again to turn it off.
Pressing the "F" pneumatic button again switches to the next
pre-set cycle no. 2; press it again to turn it off.
Proceed in the same manner to switch to the other
chromotherapy cycles:
1.
fast random
2.
slow nuanced
4.
shaded colours
5.
red
6.
green
7.
blue
8.
yellow
32
W1
W2
A
e control keyboard.