EN
spa or servicing the electrical components.
DON'T:
The cord may not be properly grounded and the connection
is a shock hazard. An extension cord may cause a voltage
drop, which will cause overheating of the jet pump motor and
motor damage.
serviceable parts inside.
ground system is therefore required, with sensitivity meeting
the relevant standards.
GROUNDWIRE.
to the electrical system.
EQUIPOTENTIAL CONNECTION.
The equipment must be connected to the equipotential
system of the room and duly fastened to its terminal to be
found in the product.
BLOWER
Connect the blower to the spa, making sure to create a siphon
about 20 cm high with respect to the edge of the spa, and as
close to it as possible.
ATTENTION: The siphon is mandatory and necessary to prevent
the water from entering the blower piping and from coming into
contact with live parts (in case of failure of the non-return valve,
factory installed on the spa side).
Insert the aromatherapy system on the blower, insert the
as indicated.
the cap and replacing it with a new one (the cartridges are
available from authorised dealers and Service Centres).
SAND FILTER
LOADING THE SAND
During installation, before loading the water in the system, load
This is done as follows:
heater (or exchanger, if installed) and remove the selector
valve; cover the pipe opening by means of the flange
(supplied) and pour the quartz sand inside the container.
Pour the sand slowly, distributing it well around the pipe,
making sure the pipe does not move from its seat.
be necessary to replace the sand; remove any residue from
the edge of the container.
Reassemble the selector valve by reconnecting the
previously removed pipes then making the connections to
FUNCTIONS
RINSE
3
5
BYPASS
TO POOL
BACKWASH
The functions of the selector valve handle are:
0 - WINTERISE: for when the spa is not used and helps
1 - FILTER: position of normal use where the water coming
distribution system, flows back up through the return
connection, to then enter the pool through the nozzles.
2 - BACKWASH
the drain piping is connected, dragging with it the deposit
3 - RINSE: in this position, the water is discharged in the drainage
sand (during system start-up, immediately after having loaded
4 - BYPASS TO WASTE: this is a by-pass position of the selector
valve. It is used to drain the spa water (periodic emptying)
the joint connected to the drain.
5 - BYPASS TO POOL: this is a by-pass position of the selector
valve. It can be used to increase recirculation speed and
therefore, the power of the jets on the return nozzles in the
28
FILTER
BYPASS
1
TO WASTE
4
0
WINTERIZE
6
CLOSED
2