Regularly clean the filter cover.
Remove filter cover and blow it out with
dry compressed air.
Gears
NOTE
Do not loosen the screws on the gear head
during the warranty period.
Non-compliance will deem the guarantee
obligations of the manufacturer null and void.
Replacement of wear parts
Change Velcro pad
Remove the battery.
Remove the polishing tool.
Place machine on its back.
Release and remove screws with Torx
wrench (1.).
Remove worn Velcro pad (2.).
Remove contaminants from interior.
24
XFE 15 125 18.0-EC / XFE 15 150 18.0-EC / XCE 8 125 18.0-EC
Align securing holes and fit new Velcro
pad (3.).
Insert screws and tighten with Torx
wrench (4.). (Tightening torque 2.5-3.0 Nm
(1.8-2.2 ft. lb.))
Carry out test run. Check for imbalances
and vibrations.
CAUTION!
An incorrect torque setting can damage the
tool and the surfaces being worked on.
Repairs
Repairs may be carried out by an authorised
customer service centre only.