3.2 DESCRIPTION OF TERMINALS, CONNECTORS AND
JUMPERS
Left terminal board
NO
Normally-open relay contact for secondary door opener
C
Common relay contact for secondary door opener
SP
Door open sensor terminals
PA
Contact for pedestrian electric lock button input
Right terminal board
-
Negative terminal for local power supply
+
Positive terminal for local power supply
SE-
Capacitive discharge electric lock terminals with hold current
SE+

4 WIRING INSTRUCTIONS

Remove the insulation sheath of the CAT5 cable (with rigid wires) for at least 40mm.
Strip the conductors for no more than 6mm.
Insert the wires in the connector respecting the positions and colour codes shown (Standard T568B).
1
Proceed as shown below if a wire needs to be removed from the connector:
Wires with cross-section area of 0.5 mm
crosssection area smaller than 0.5 mm
Refer to the instructions contained in the system manual for maximum distances and configuration
operations.
DS1060-133A
8
1
2
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
Wire No.
1
White-Orange
2
3
4
5
6
7
8
1
Wire colour
Orange
White-Green
Blue
White-Blue
Green
White-Brown
Brown