3.2 DESCRIPTION OF TERMINALS, CONNECTORS AND
JUMPERS
Left terminal board
NO
Normally-open relay contact for secondary door opener
C
Common relay contact for secondary door opener
SP
Door open sensor terminals
PA
Contact for pedestrian electric lock button input
Right terminal board
-
Negative terminal for local power supply
+
Positive terminal for local power supply
SE-
Capacitive discharge electric lock terminals with hold current
SE+
4 WIRING INSTRUCTIONS
•
Remove the insulation sheath of the CAT5 cable (with rigid wires) for at least 40mm.
•
Strip the conductors for no more than 6mm.
•
Insert the wires in the connector respecting the positions and colour codes shown (Standard T568B).
1
•
Proceed as shown below if a wire needs to be removed from the connector:
Wires with cross-section area of 0.5 mm
crosssection area smaller than 0.5 mm
Refer to the instructions contained in the system manual for maximum distances and configuration
operations.
DS1060-133A
8
1
2
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
Wire No.
1
White-Orange
2
3
4
5
6
7
8
1
Wire colour
Orange
White-Green
Blue
White-Blue
Green
White-Brown
Brown
2
11