8. Troubleshooting

If the c-Go fails to perform properly, please check the status display on the unit first.
Two flashing displays indicate an error status. The error code may be determined by
observing how many times the displays are flashing. In case of an error the following
flashing sequence will run:
Problem
LED not flashing
All LEDs are blin-
king quickly
Table 1: Fault diagnostics
Error code Description
1, 2, 3
Internal error
4
Temperature too
low
5
Temperature too
high
7
Current voltage too
high
9
Battery reverse
polarity
Table 2: Error codes
Upon elimination of the error cause the c-Go may be rebooted by disconnecting the
unit briefly from the power supply.
GB6
Mögliche Ursachen
Mains supply not connected
Vehicle battery voltage low
c-Go or supply cable failure
A problem has been found
Possible causes and solution(s)
Reboot the c-Go. If the problem continues,
contact the service department
Mode the battery and the c-Go to a warmer place.
If the problem continues, contact the service de-
partment
Allow the c-Go to cool down for 15 minutes.
Restart the charging procedure.
Avoid exposure to direct sunlight.
If the problem persists, contact the service depart-
ment
Check the battery and the wiring.
Restart the charging procedure.
If the problem persists, contact the service depart-
ment
Disconnect the battery and check the polarity
Lösung
Check mains supply/connection
Check vehicle battery charging
procedure
Please contact the service de-
partment
Count the number of flashes
between the pauses and consult
table 2

Publicité