7.5
Inspection and cleaning of the electrical components
Please check again if the power plug is disconnected. Check the laying of the electric cables
visually. Cables may not be laid across sharp corners or hot places and may not exhibit
cracks / blank points. Replace cables in case of cracks, etc. Clean electrical components with
brush upon strong dust formation and scrape off any corrosion residue from electrical contacts
7.6
Completion of servicing, trial run
After the performance of servicing reconnect all contacts and conduct a trial run.
8
Fire Safety Regulations
All flammable components, furniture or decorative materials, for example, in the
proximity of the stove have to be protected against the influence of heat. Observe in
particular all locally valid fire safety provisions and regulations.
Dimension
Value
A
80 cm
B
40 cm
C
20 cm
D
20 cm
Verbindungsstück
Connection component
C
C
Example with chimney connection component within the
Minimum spacing to hot air outlets / radiation range
Minimum spacing to hot air outlets with ventilated radiation screening / radiation
range
Minimum spacing exterior to the radiation range
Minimum insulation of flue pipe in case of wall insertion with insulation (not back-
ventilated)
Pictures illustrating fire safety spacings
C
B
A
belüfteter Strahlungsschutz
Ventilated radiation screen
fireplace room
Significance
D
D
C
30 cm
50 cm
Example with chimney connection component inserted
through the wall
45 / 96
Feuerfester
Fire-proof coating /
Belag /
base plate
Bodenplatte
30 cm