Teddington INOA-R 6 Manuel D'utilisation Et Installation page 44

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
For your safe use in winter, it's strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
MODEL
Rated Current
A
Breaker
Rated Residual
Action Current
mA
Fuse
A
Power Cord(mm
2
Signal cable(mm
2
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
Fuse
Breaker
INOA- R
INOA- R 6
10.5
30
10.5
3×2.5
3×2.5
3×0.5
3×0.5
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
INOA- R
INOA- R
8
12
14
14.5
18.0
21.0
30
30
30
14.5
18.0
21.0
3×4
3×4
3×0.5
3×0.5
- 13 -
For installers and professionals
INOA- R
INOA- R
18M
18T
24.0
9.0
30
30
24.0
9.0
3×6
5x2.5
3×0.5
3×0.5
10m, wire diameter must be
INOA- R 24
12.0
30
12.0
5x2.5
3×0.5