Connecting The Electrical Cables For The Sc41Xx & Sc5Xxx Models; Connecting The Electrical Cables For The S41Xx & S5Xxx Models - Qlima S5025 Manuel D'installation

Masquer les pouces Voir aussi pour S5025:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
11. CONNECTING THE ELECTRICAL CABLES.
11.1 Connecting the electrical cables for the SC41xx & SC5xxx models.
a.
4 ,5 Meter cable for electrical connection between indoor and outdoor unit is delivered with the pac-
kage and is included in the refrigerant piping sleeve (indoor unit).
B.
The electrical cable is provided with an electrical quick connector.
c.
The outdoor unit is also provided with electrical quick connector.
d.
Remove the control cover from the outdoor unit by loosening the screw.
e.
C lick the connector of the interior unit into the connector of the exterior unit and secure the cable
to the terminal block with the cable clamp mounted on it.
f.
T he earth cable must be connected directly to the metal plate on which the terminal strip is mounted.
The location is indicated with the symbol
Cover plate
Cover
Figure 17
g.
O nly connect the power supply cable once the entire installation of the air conditioner has been
completed.
G
TAKE CARE
For models with a capacity < 4.5 kW plug the plug into a wall socket.
For models with a capacity > 4.5 kW connect the power supply cable directly the power source.
Do not use a plug and socket as the high current can damage both the terminals of the plug and
the socket and even cause a fire.
Outdoor unit
L
Outdoor unit
Control cover
Screw
or
Figure 18
To indoor unit
11.2 Connecting the electrical cables for the S41xx & S5xxx models.
a.
Connect the cable to the indoor unit
4
58
58
L
N
S
N
S
'click'
Plug connector
Secure the cable with cord clamp
b.
Indoor/Outdoor connection cable should be H07RN-F type, 2,5 mm².
c.
T o mount the cable to the interior unit: Remove the front panel and the cover plate of the terminal
strip on the right hand side of the interior unit. Figure 19.
Front Panel
Front panel
Electronic box
Cover plate
cover
Figure 19
d.
T he cable can be fed through from the back of the interior unit to the terminal strip.
e.
Connect the electrical wires to the terminal strip, for the correct location see fig 20.
S41xx - S5xxx - SC41xx - SC5xxx
L
N
S
Figure 20
to indoor unit
f.
A ttach the cable of the indoor unit. Remove the cover plate of the terminal strip of the outdoor unit.
g.
C onnect the connection cable to the terminal strip (zie picture 21). Attach the cables so that the posi-
tion of the wires matches the connection of the cables to the indoor unit (the letters L N S, the earth
cable and, for the models with a capacity > 6.0 kW, the numbers 1 + 2).
h.
T he earth cable must be connected directly to the metal plate on which the terminal strip is mounted.
The location is indicated with the symbol
i.
I n models with a capacity of up to 6.0 kW, the supply cable is already preassembled on the inside
part. In models with a capacity > 6.0 kW, the supply cable must be connected to the outside part (the
supply cable is not included).
j.
O nly connect the power supply cable once the entire installation of the air conditioner has been
completed.
L
N
S
G
TAKE CARE
For models with a capacity < 4.5 kW plug the plug into a wall socket.
For models with a capacity > 4.5 kW connect the power supply cable directly the power source.
Do not use a plug and socket as the high current can damage both the terminals of the plug and
the socket and even cause a fire.
S41xx - S5xxx - SC41xx - SC5xxx
to outdoor unit
Figure 21
4
59
59

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S5032S5048Sc5025Sc5032Sc5048Sc4125 ... Afficher tout

Table des Matières