Hood Transition
Assembly of the Transition
10"
(254 mm)
Duct
1"
(25.4 mm)
x 2
4
5 16
/
"
(110 mm)
17½ʺ
17½ʺ
17½ʺ
(444 mm)
(444 mm)
(444 mm)
Figure 3: Hood Transition Dimensions
1. A minimum height clearance of 10¼'' (260 mm) is
needed above the hood for transition mounting.
10¼ʺ
10¼ʺ
10¼ʺ
(260 mm)
(260 mm)
(260 mm)
ʺ
ʺ
13
13
13
12
12
12
/
/
16
16
16
(325 mm)
(325 mm)
(325 mm)
English 8
Figure 2: Transition Dimensions
"
"
4
4
5/
5/
21¾ʺ
21¾ʺ
21¾ʺ
16
16
16
(552 mm)
(552 mm)
(552 mm)
(502 mm)
(502 mm)
(502 mm)
Figure 4: Transition Height
2. Remove transition from inside of hood. Discard
brackets attaching transition to the inside of hood.
3. Align mounting holes at base of transition with the
mounting holes of the 1/2'' (13 mm) flange located at
the top or rear of the hood (Figure 5).
4. Fasten transition to hood using two (2) 1'' (25.4 mm)
sheet metal screws included with hood (Figure 5).
5. Seal connection between transition and hood with
aluminum tape. DO NOT use duct tape (Figure 5).
6. Remove tape holding damper closed.
Figure 5: Transition Connection