Toshiba Carrier RAV-SP180KRT-UL Manuel D'installation page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

+001111052201_00Ta.book Page 39 Friday, November 20, 2009 11:45 AM
High-Wall Type
F06
F07
F08
F10
F12
F13
F15
F29
F31
H01
H02
H03
H04
H06
L03
L07
L08
L09
39-EN
Outdoor unit temp.
ALT
Outdoor
sensor (TE/TS) error
ALT
TL sensor error
Outdoor
Outdoor unit outside
ALT
Outdoor
air temp. sensor error
Indoor unit room
ALT
temp. sensor (TA)
Indoor
error
ALT
TS sensor error
Outdoor
Heat sink sensor
ALT
Outdoor
error
Temp. sensor
ALT
Outdoor
connection error
Indoor unit, other
SIM
Indoor
P.C. board error
Outdoor unit P.C.
SIM
Outdoor
board
Outdoor unit
compressor
Outdoor
breakdown
Outdoor unit
Outdoor
compressor lock
Outdoor unit current
Outdoor
detect circuit error
Case thermostat
Outdoor
operation
Outdoor unit low-
pressure system
Outdoor
error
Duplicated header
SIM
Indoor
indoor units
Group line in
SIM
individual indoor unit
Indoor
Indoor group address
SIM
Indoor
not set
Indoor power level
SIM
Indoor
not set
– 39 –
Installation Manual
Outdoor temp. sensors (TE/TS),
outdoor P.C. board --- Open-
circuit or short-circuit of the heat
exchanger temp. sensor was
detected.
TL sensor may be displaced,
disconnected or short-circuited.
Outdoor temp. sensor (TO),
outdoor P.C. board --- Open-
circuit or short-circuit of the
outdoor air temp. sensor was
detected.
Room temp. sensor (TA), indoor
P.C. board --- Open-circuit or
short-circuit of the room temp.
sensor (TA) was detected.
TS sensor may be displaced,
disconnected or short-circuited.
Abnormal temperature was
detected by the temp. sensor of
the IGBT heat sink.
Temp. sensor (TE/TS) may be
connected incorrectly.
Indoor P.C. board --- EEPROM
error
Outdoor P.C. board ---- In the
case of EEPROM error.
Current detect circuit, power
voltage --- Minimum frequency
was reached in the current
releasing control or short-circuit
current (Idc) after direct
excitation was detected
Wiring error of compressor (open
phase)
Compressor circuit ---
Compressor lock was detected.
Wiring error of compressor (open
phase)
Current detect circuit, outdoor
unit P.C. board --- Abnormal
current was detected in AC-CT or
a phase loss was detected.
Malfunction of the case
thermostat
Current, high-pressure switch
circuit, outdoor P.C. board --- Ps
pressure sensor error was
detected or low-pressure
protective operation was
activated.
Indoor address setting error ---
There are two or more header
units in the group.
Indoor address setting error ---
There is at least one group-
connected indoor unit among
individual indoor units.
Indoor address setting error ---
Indoor address group has not
been set.
Indoor power level has not been
set.
Entire
stop
Entire
stop
Operatio
n
continue
d
Auto-
reset
Entire
stop
Entire
stop
Entire
stop
Auto-
reset
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Toshiba

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rav-sp240krt-ul

Table des Matières