16
Standard, Economy, Sleep, and
Standby Modes
Mode/Prog: This button is used to switch between
standard, economy, and sleep modes.
1.
Press MODE/PROG to enter mode programming.
2.
Press the DOWN button to cycle through to the
desired mode.
3.
Press MODE/PROG to confirm selection.
Standard Mode: This is programmed to maintain the
desired temperature. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least two minutes. The
"STAND" icon will display until the mode is changed.
Economy Mode: Economy mode heats the spa to the
set temperature only during filter cycles. The "ECON"
icon will display until the mode is changed. Pressing
the JETS 1 button while in economy mode puts the
spa in standard-in-economy mode, which operates the
same as standard mode but reverts back to economy
mode automatically after one hour.
time, pressing the MODE/PROG button will revert to
economy mode immediately.
Sleep Mode: Sleep mode heats the spa to within 11˚C
of the set temperature only during filter cycles. The
"SLEEP" icon will display until the mode is changed.
Standby Mode: Pressing "Warm" or "Cool" then "Jets
2" will turn off all spa functions temporarily. This is
helpful when changing a filter. Pressing any button
resets the spa.
Jets 1 and Jets 2
Press the JETS 1 button once to turn pump 1 on or off
and to shift between low and high speeds if equipped.
If left running, the low speed turns off after two hours
and the high speed turns off after 15 minutes. On
non-circulation systems, the low speed of pump 1
runs when the blower or any other pump is on. It may
also activate for at least two minutes every 30 minutes
to detect the spa temperature and then to heat to
the set temperature if needed, depending upon the
mode. When the low speed turns on automatically, it
cannot be deactivated from the panel; however, the
high speed may be started.
Option (Optional Blower)
Press the OPTION button to turn the optional
equipment on and off. If left on, the equipment will
automatically turn off after 15 minutes.
www.calspas.com
Light
Press the LIGHT button to turn the spa light on and
off.
Invert
Press the INVERT button to change the numbers in the
display to read upside down. Another press returns
the display to the right-side-up position. This enables
you to read the display while you are in the spa.
Locking the Panel
To lock the panel:
Press TIME, JETS 1, and the UP button within three
seconds. When locked, the panel will display "LOCK".
All buttons are frozen except the TIME button.
To unlock the panel:
Press TIME, JETS ,1 then the DOWN button within
three seconds.
Setting the Temperature Lock
During this
To activate the temperature lock:
Press the UP or DOWN button, TIME, JETS 1, then the
UP button within three seconds. The panel will display
"TEMP LOCK" when the set temperature is locked.
To unlock the set temperature:
Press the UP or DOWN button, TIME, JETS 1, then the
DOWN button..
Circulation Pump (optional)
If your system is equipped with a circulation pump,
it may be configured to work in one of two different
ways:
1.
The circulation pump operates continuously (24
hours) with the exception of turning off for 30
minutes at a time when the water temperature
reaches 1.7˚C above the set temperature (most
likely to happen in very hot climates).
2.
The circulation pump will come on when the
system is checking temperature, during filter
cycles, during freeze conditions, or when another
pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end
times of each cycle are programmable. To program, set
the time as instructed above, then press MODE/PROG
to advance to the next setting (or to exit after the last
setting). The default filter cycles are as follows: