Final Operations - Fulgor Milano FCLHD 8041 HID TS BK Instructions Pour L'installation Et L'utilisation

Masquer les pouces Voir aussi pour FCLHD 8041 HID TS BK:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SEM16-E (Dwg. 17)
After having removed the four screws securing
the air outlet joint to the main structure (Fig. 16), it
is possible to rotate the joint with the aim of orien-
ting the air outlet according to one's needs (Fig.
17). Place the motor SEM16-E under the hob, as
shown in Fig. 15. Place the plastic box containing
the electronic board on the bottom of the cabinet,
as shown in Fig. 15. According to the position of
the air outlet, the plastic box containing the elec-
tronic board can be placed either on the left or the
right side of the motor and it must be secured by
means of the provided screws.
DUCTING
The telescopic metallic ducts (x2) must be placed
in correspondence with the air inlet of the blower
assembly (Fig.7), securing them by means of the
provided screws. The internal metallic duct must
be lifted up until it reaches the filtering case and
then it must be secured by means of the provi-
ded screws (Fig. 8). The air flow passage must
be sealed with the provided duct tape, as shown
in Fig. 9.
IN CASE OF RECIRCULATING OPERATION
The air outlet of the product must be connected
to the opening in the cabinet so as to recirculate
the exhausted air in the kitchen. Charcoal filters,
to be purchased separately, are needed in this
configuration. They must be installed as shown
in Fig. 10. Charcoal filters are located right under
the grease filters, so they must be installed befo-
re the grease filters. A ducting kit with grill (on the
end to be installed in the cabinet) is also available
for separate purchase.
28
EN
IN CASE OF DUCTING OPERATION
The air outlet of the product must be connected to
the outside of the house. The ducting to be instal-
led from the air outlet of the product to the outside
of the house is not provided with the appliance.
The product is equipped with plastic flanges, to
connect ducts of different sections to the motor.
The provided flanges have the following dimen-
sions:
230x80mm
220x90mm
220x55mm (only recommended for recirculating
configurations and for short stretched ducting).

FINAL OPERATIONS

Install the grease filters in the specific seat, letting
them through the central opening of the hob, see
Fig. 11. To close the central opening of the hob,
place the metal grill on top of it, as shown in Fig.
12.
Keep a distance of 15 cm from the bottom of the
induction hobs to allow a correct circulation of the
air.
FCLHD 9041 HID TS BK