410-00352
3.3. Operating modes
There are several operating modes available. Below you will find an overview of all operating modes and their function. See § 4.1 for information about programming an operating mode.
Operating mode
Description
Standard control
R 120 s
Roller shutter runtime 120 seconds
0
Output activated for 120 seconds. Roller shutter moves in the selected direction.
J 120 s
Blind runtime 120 seconds
1
1. Press the button <1.6 s = slat adjustment.
Output activated for as long as the button is pressed.
2. Press the button >1.6 s = self-maintained for 120 s.
Output activated for 120 s, blind moves in the direction selected
Runtime dependent control
To be able to use these functions, a runtime must be measured
Operating mode
Description
R 100 %
Roller shutter 100% runtime
3
Output activated for programmed runtime. The roller shutter moves in the selected direction
R Pos. 1
Change roller shutter position
4
Direction OPEN (A): roller shutter moves into the upper end position and switches off.
Direction CLOSE (B): roller shutter moves into the programmed position (POS).
Different positions can be programmed for each output.
Note: The roller shutter opens completely before moving to the programmed position.
R Pos. 2
5
Programmed positions are always approached from the upper end position
R Pos. 3
6
Blind 100% runtime
J 100 %
7
1. Press the button <1.6 s = slat adjustment.
Output activated for as long as the button is pressed.
2. Press the button >1.6 s = self-maintained for the programmed runtime.
Output activated for programmed runtime, blind moves in the selected direction
J Pos. 1
Change blind position
8
1. Press the button <1.6 s = slat adjustment.
Output activated for as long as the button is pressed.
2. Press the button >1.6 s.
J Pos. 2
Direction OPEN (A): Blind moves into the upper end position and switches off.
9
Direction CLOSE (B): Blind moves into the programmed position (POS).
Different positions can be programmed for each output.
Note: The blind opens completely before moving to the programmed position. Programmed
J Pos. 3
positions are always approached from the upper end position
A
J RT
Measure reversing time
After every STOP command received whilst closing (CLOSE), the blinds move in the OPEN direction for the time specified. When changing positions, the blinds also reverse as soon as the
position has been reached (only with operating modes 7 to A)
max.
Push-button
C
36 s
The outputs are only activated for as long as the button is held down (10 or 36 s. depending on
the type of Easywave switch). In 3TB-programmed transmitters, the STOP button (C/D) does not
have a function
Lock mode
HOLD
H
In this mode, programmed transmitters can lock the output in the CLOSE direction
Delete or RESET mode
DEL
L
EN
2
3-button operation (3TB)
2-button operation (2TB)
transmitter button
transmitter button
A
B
C
D
A
OPEN
CLOSE
STOP
STOP
OPEN
STOP with the opposite direction
OPEN
CLOSE
STOP
STOP
OPEN
Slat adjustment
STOP with the opposite direction
<1,6 s: slat adjustment
3-button operation (3TB)
2-button operation (2TB)
transmitter button
transmitter button
A
B
C
D
A
OPEN
CLOSE
STOP
STOP
OPEN
STOP with the opposite direction
OPEN
POS
STOP
STOP
OPEN
STOP with the opposite direction
OPEN
CLOSE
STOP
STOP
OPEN
<1,6 s:
STOP with the opposite direction
Slat adjustment
<1,6 s: Slat adjustment
OPEN
POS
STOP
STOP
OPEN
<1,6 s:
STOP with the opposite direction
Slat adjust- ment
<1,6 s: Slat adjustment
OPEN
CLOSE
No
No
OPEN
function
function
active
inactive
active
inactive
active
B
C
D
CLOSE
OPEN
CLOSE
CLOSE
OPEN
CLOSE
B
C
D
CLOSE
OPEN
CLOSE
POS
OPEN
STOP
CLOSE
OPEN
CLOSE
POS
OPEN
POS
CLOSE
OPEN
CLOSE
inactive
active
inactive
PM410-00352R21224