E
Enable / disable automatic advance
This function enables the device to automatically adapt the system start-up time in order to have the
desired temperature at the time set.
The advance is calculated according to the difference between the temperature detected and the one set.
It is possible to have an advance of up to a maximum of three hours prior to the time that has been set for
the temperature to be reached.
Example of operation
If the device is programmed to have a temperature of 20 °C at 7.00 a.m. and the automatic advance is not
active, at 7.00 a.m. the system will come on, without however guaranteeing 20 °C at 7.00 a.m.
If automatic advance is on the programmable thermostat will bring forward switching on the system
so as to try to reach 20 °C at 7.00 a.m.; thanks to the auto-recognition mechanism, the programmable
thermostat stores the thermal parameters of the room in order to be more accurate in subsequent days in
terms of attaining the thermal objective set.
F
Changing the calibration of the temperature
detection probe
If the location of the device does not permit suitable
detection of the temperature, it is possible to change
the temperature detected by ±3 °C with increases of a
tenth of a degree.
arrows E to change the data detected by
Use the
the desired value and press the
the next parameter to be configured.
arrows F to activate (ON) or
Use the
deactivate (OFF) the automatic advance and press
the
button to move on to the next parameter
to be configured.
button to move on to