Fault Diagnosis - Truvox International Valet Battery Backpack Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FAULT DIAGNOSIS

The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
Trouble
Machine
not
working
charger indicates the battery is
fully charged
Only red LED on charger
module is illuminated
No LED Display
Loss of vacuum suction
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
4
Reason
and
Battery
terminal
connected
Motor overload protector has
tripped
Broken switch
Battery low voltage
Battery low voltage
Battery faulty
Dust bag full
Blocked hose or wand
Motor is not running
Filter restricted
Remedy
is
not
Check that the battery is fully
inserted into the machine
Wait for 20 minutes to allow
the motor temperature to reach
room temperature. Then try
again.
Contact service agent
Charge the battery for 2.5
hours and then try again.
Charge the battery for 2.5
hours and then try again.
Contact Service Agent
Replace bag
Remove obstruction
Contact service agent
Remove filter and clean
03-19

Publicité

Table des Matières
loading

Table des Matières