AUTODIAGNOSTIC LEDS
D
e
scription of autodiagnostic LEDs.
Green LED
Fixed: Correct operation.
Slow blinking: Programming activated.
Quick blinking: Programming finished.
Red LED
Fixed: Programming error, go through the steps from the
beginning.
Off: Correct operation.
PROGRAMMING
P
r
ogramming the converter.
If using this module as a column encoder (see page 26), a different column code should be
programmed in each converter, following the steps described below.
golmar
1
0
0
If there are more converters, repeat the previous steps introducing a different column code for
each converter.
If during one of these processes the red LED switches on, restart programming from the
Beginning.
13:15
Activate the converter programming by setting the dip switch
number 4 to ON.
The door panel will emit a tone and the green LED
on the converter will begin to slow blinking, indicating
that programming has begun.
0
Introduce the column code to program, followed by three
O.K.
zeros, then press the bell button.
To indicate that the equipment has been correctly
programmed, the door panel will emit a tone and the
green LED on the converter will begin to quick blinking,
indicating that programming has begun.
Exit programming by setting the dip switch number 4 to OFF
and pressing the C button on the door panel.
The autodiagnostic LEDs are placed next to
the configuration dip switch.
Access the door panel programming mode, pressing
the key button followed by the installer secret code
(factory default 1315), just as indicated in the
door panel manual.