The fresh air flow required to provide air for combustion is:
- PSR 400 GE
6,4 m3/h
- PSR 600 GE
12,8 m3/h
- PSR 900 GE
19,2 m3/h
General conditions for installation
The installation and maintenance of the appliance must be carried out in accordance with the
current regulations and rulebook, in particular:
Regulations for the prevention of fire and panic in establishments to which the public is
admitted:
General provisions
For all appliances:
Article GZ
Installations using combustible gases and liquid
hydrocarbons.
Next, depending on the use :
Article CH
Heating, ventilation, refrigeration, air conditioning and the
production of steam from hot water in sanitary installations.
Article GC
Installation of appliances to be used for catering
Specific provisions for each type of establishment to which the public is admitted (hospitals,
shops, etc )
Changing the gas
Important: Do not rebore the injectors.
Table of gas categories, according to country of destination of the appliance
Country of destination
Category
France/Luxembourg
II2E+3+
II2E+3B/P
Germany
II2E3B/P
Austria
II2H3B/P
Belgium
I3+
I2E
Sweden, Denmark,
II2H3B/P
Finland
Spain
II2H3+
II2H3P
Netherlands
II2L3B/P
II2L3P
Norway
I3B/P
Iceland/Greece/United
II2H3+
Kingdom/Italy/Portugal
Injector N°
Gas
Injector n°1
G30 / G31
Injector n°2
G30 / G31
Injector n°3
G20 / G25
Injector n°4
G25
Injector n°5
G25
Injector n°6
G31
Air adjustment
Diagram showing measurement of the air adjustment mark in the table above.
Gas
Pressures
Diameter of
injector
G20/G25
20/25
135
G30/G31
28-30/37
90
G20/G25
20/25
135
G30/G31
50
85
G20
20
135
G25
20
150
G30/G31
50
85
G20
20
135
G30/G31
50
85
G30/G31
28-30/37
90
G20/G25
20/25
135
G20
20
135
G30/G31
30
90
G20
20
135
G30/G31
28-30/37
90
G20
20
135
G31
50
85
G25
25
140
G30/G31
30
90
G25
25
140
G31
50
85
G30/G31
30
90
G20
20
135
G30/G31
28-30/37
90
Pressures
Diameter
Butane/Propane 28-30/37
90/100
Butane/Propane 50
85/100
Natural Gas
20-25
135/100
Natural Gas
25
140/100
Natural gas
20
150/100
Propane
50
85/100