Type of battery settings
To access to the configuration of batteries, when you are on the VIEW_SIMULT.
1
Access to the battery that you want to set, as defined above (for example:
VIEW_BAT1).
Once you are viewing the desired battery,
2
press _CONFIG_.
So you access to the menu setup of the
affected battery.
Information on the battery configuration settings:
Parameters
Battery Capacity
Shunt
High Voltage Alarm
Low Voltage Alarm
Low Capacity Alarm
High Temperature Alarm
www.busse-yachtshop.de | info@busse-yachtshop.de
Choice of settings
1 to 2000 Ah
1 to 300 A
0 to 35 V
0 to 35 V
1 to 100 %
1 to 70 ° C
37
Battery Monitor JBNUM-CPS3
Example : Configuration Battery 1
Principle
Battery capacity in amp-hours (Ah). It is the
ability to a discharge in 20H and at 20° C
Default: 100 Ah
Stepsize : 1 Ah
Shunt
value
on
which
measurement board, in Amp. It must be a shunt
XXX A / 100 mV.
Default: 250 A
Stepsize : 1 A
When the battery voltage rises above this value,
after 5 seconds, an alarm is actived.
Default: 16 V
Stepsize : 0,1 V
When the battery voltage falls below this value,
after 30 seconds, an alarm is actived.
Default: 10,5 V
Stepsize : 0,1 V
When the battery capacity falls below this value,
an alarm is actived.
Default: 50 %
Stepsize : 1 %
When the battery temperature rises above this
value, an alarm is actived.
Default: 60°C
Stepsize : 1° C