Electrical Connection; Electrical Connection Of Your Hob - Burg BCA60-TR Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Electrical connection of your hob

· Before proceeding with the electrical connection, verify that the current
carrying capacity of the system and the socket is adequate for the maximum
power rating of the hob.
· Electrical installation of the residence and the electrical current plug in
use must be earthed and conform with safety regulations.
· If there is no dedicated hob circuit and fused switch, they must be installed
by a qualified electrician before the hob is connected.
· The fused switch must be easily accessible once the hob has been
installed.
· Do not use adaptors, multiple sockets and/or extension leads.
· This appliance conforms with the requirements ofthe following EEC
Directives:
1. Vitroceramic hob EEC/73/23 and 93/68, EEC/89/336 relating to
radio interference,
2. EEC/89/109 relating to contact with foods.
· A circuit breaker with a contact opening of at least 3 mm, rated 32A and
delayed functioning type must be installed in the supply circuit.
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
Supply cable connection can be differ according to terminal box type.
· The supply cable must be H05VV-F 3X2,5 mm² / 60227 IEC 53. You will
find the connection diagram shown on the back of your appliance.
· During installation, please insure that isolated cables are used. An incorrect
connection might damage your appliance. The guarantee will not cover
such damages.
· All repairs must be carried out by an authorised service personal or a
qualified electrician.
· Unplug your appliance before each maintenance. For reconnection, follow
the connection diagrams.

ELECTRICAL CONNECTION

/
5x1.5 mm² 380V 3N~
3x2,5 mm² 220V~
5x1.5 mm² 400V 3N~
3x2,5 mm² 230V~
5x1.5 mm² 415V 3N~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~