Water Supply
Observe and follow all local building codes when installing this
appliance.
Attach the supplied water line adapter (Figure 6) to the water
valve inlet on the back of the ice machine (See Figure 5). Be sure
the rubber washer is in place in the inlet valve nut. Bend the
1/4" copper tubing to suit your installation being sure not to kink
the tubing. Use 1/4" copper tubing for your water supply which is
available at any local hardware or plumbing supply store. A shut-
off valve is recommended. NOTE: DO NOT USE A SELF-PIERCING
TYPE VALVE. Connect the copper tubing water supply to the cop-
per tubing from the adapter assembly with the provided brass
union. Secure the water supply line to the back of the cabinet
with the screw and clamp provided in the corner of the back
panel. (See Figure 5).
Water pressure must be at a minimum of 20 psi for proper op-
eration and a maximum of 120 psi.
Make certain all water connections are watertight after instal-
lation. Form the tubing so that it will not vibrate against the
cabinet body or kink when your ice machine is set in position.
NOTE
Do not use any thread sealers on these water line fittings.
Do not use a "Reverse Osmosis" Filtering Device.
Softened water is not recommended. This will produce soft
cloudy ice cubes that will stick together.
De-ionized water is not recommended. This water will not
form solid ice cubes.
Compression Fitting

INSTALLING THE WATER SUPPLY

Rubber Washer
Adapter
Compression Nut
Back view of
ice machine
Fitting Valve
(*) Supplied by Customer
Figure 6
6
Figure 5
1/4" Copper Water
Supply Line (*)
From Water Supply to
Ice Maker
Water
Supply
Line
Clamp and
Screw
Water supply
inlet