IMPORTANT SAFETY INSTRUCTIONS
SAFETY ALERT SYMBOL
The symbol above is used to call your attention to instructions
concerning your personal safety. It points out important safety
precautions. It means "ATTENTION! Become Alert! Your
Personal Safety is involved!" Read the message that follows
and be alert to the possibility of personal injury or death.
DANGER
A person who has not read and understood all operating
Instructions is not qualified to operate this product.
DANGER
Do not immerse or spray any component of the
controller system with liquid.
Keep volatile or combustible material away from
controller when in use.
If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the
equipment can be impaired.
The unit must be connected to Protective Earth
Grounding.
Keep sharp metal objects away from heater.
Do not modify this product. Modification will void
warranty.
Failure to observe these warnings may result in electric shock,
risk of fire, and personal injury.
WARNING
End-User Must Comply to the Following:
Only qualified personnel are allowed to connect the
electrical wiring.
All electrical wiring must follow local electrical codes.
The person who performs the final installation / wiring
must be qualified for this work.
The end-user is responsible for providing a suitable
disconnecting device.
The end-user is responsible for providing suitable over
-protection device. It is highly recommended that a
ground fault circuit breaker be used.
Failure to observe these warnings may result in personal injury
or damage to the heater.
®
© BriskHeat
Corporation. All rights reserved.
SDCE Digital Benchtop Temperature Controller
DANGER
Immediate hazards which WILL result in severe personal injury or
death.
WARNING
Hazards or unsafe practices that COULD result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor personal
injury or property damage.
CAUTION
Inspect all componentsbefore use. Do not use
controller if any component is damaged.
Do not repair damaged or faulty controller.
Do not crush or apply severe physical stress on any
component of system, including cord assembly.
Unplug controller when not in use.
Unit must be mounted away from vibration, impacts,
water and corrosive gases. The box containing the
controller should be stored indoors in a dry, protected
area. Under no circumstances should condensations,
rain, snow or water be allowed to come in contact with
the box or the controller while in storage.
Failure to observe these warnings may result in personal injury
or damage to the controller.
ATTENTION
For most accurate temperature measurements, do not install
probe cable near power cables.
CAUTION
Ensure the controller is rated for the input power source prior to
connecting the controller to power.
3
GENERAL SPECIFICATIONS
Input Type
°C
J-type Thermocouple
- 40°C to 370°C
K-type Thermocouple
- 40°C to 482°C
RTD-type (PT100)
- 50°C to 450°C
Conditions
Storage Temperature
Temperature Limits: Ambient
Max Amps
Control Type
Part Number
Sensor Type
SDCEJA
J
SDCEKA
K
SDCERA
RTD
SDCEJB
J
SDCEKB
K
SDCERB
RTD
SDCEJC
J
SDCEKC
K
SDCERC
RTD
SDCEJD
J
SDCEKD
K
SDCERD
RTD
SDCEJE
J
SDCEKE
K
SDCERE
RTD
®
© BriskHeat
Corporation. All rights reserved.
SDCE Digital Benchtop Temperature Controller
Temperature
Accuracy
°F
- 40°F to 698°F
±(0.5% span ±1 digit
- 40°F to 899°F
@ 25°C)
- 58°F to 842°F
-20°C to 70°C
-4°F to 158°F
0°Cto 37°C
32°F to 100°F
8A
ON/OFF
Plug Type
Picture
NEMA 5-15
100-125VAC
Ferrule Ends
100-240VAC
NEMA 6-15
100-240VAC
Schuko
100-240VAC
UK Type G
100-240VAC
4