PARAMETERS

Parameter
Description
Desired heater
SP1
Set Point
temperature
High Limit
AL
Alarm set point
Alarm
Change units
Sen
Sensor Units
between °C and
°F
Deviation
d1
Hysteresis
Between On-Off
Cycle
Alarm
Change of the
AL.F
Function
alarm action
Restricted
Factory
r.P
Parameters
Programming
* Only select a parameter listed in the table that corresponds with the controllers model number being
used.
Configuration of Parameters:
1.
If the controller is in Stand-by mode, return the controller to normal operations.
2.
Press and hold the P button for approximately 5 seconds. Use the UP and DOWN buttons to
select the desired parameter to change.
3.
Press the P button to select the desired parameter. The instrument will alternatively visualize the
parameter's code and its current value.
4.
To modify the value of the parameter, press the UP and DOWN buttons.
5.
Press the P button to save the new value. The display will return to visualize only the code of the
selected parameter.
6.
Press the UP and DOWN buttons to select another parameter to modify using the steps above.
7.
To exit the programming mode, press and hold the UP button for approximately five seconds or
wait 30 seconds for the controller to automatically exit the programming mode. When the
temperature displays, the controller is no longer in the programming mode.
Stand - by:
Press and hold the U (Stand-by) button to turn on stand-by mode. The heater will not heat while the
controller is in this mode. To return the controller to normal operations, press and hold the U button
until the temperate displays on the screen.
®
© BriskHeat
Corporation. All rights reserved.
SDCE Digital Benchtop Temperature Controller
Range
Units
Default
°C
0 to 999
0
°F
°C
-999 to 999
999
°F
JC (°C)
Model
JF (°F)
-
JC
SDCE*J
*
Ca.C (°C)
Model
Ca.F (°F)
-
Ca.C
SDCE*K
*
Model
Pt.C (°C)
-
Pt.C
SDCE*R
Pt.F (°F)
°C
1 to 999
1
°F
See Alarm Settings Section
-
AL.n
Factory preset to 0
-
0
7
240V HEATER POWER CONNECTOR INSTALLATION
Note: These instructions do not apply to the SDCE*A (120V) model
®
Required Tooling: POZIDRIV
#1, wire cutter and wire stripper.
1. Place the bushing (1) and the chuck (2) over the heater
cord.
White chuck (a):
6.0 - 11.0mm (0.236 - 0.433")
Black chuck (b):
9.5 - 14.0mm (0.374 - 0.551")
2
. Prepare and strip the heater cord as shown.
3.
Insert the wire into the terminals and fasten the
clamping device with a POZIDRIV, max. torque 0.5
Nm (4.44 lb-in).
Note: The ground wire is typically a green wire.
4. Slide the insert and the chuck (1) into the housing (2).
5. Hand tighten bushing. Maximum torque 2.5 Nm (21.6 lb-in).
Important:
(a) Align the chuck by
1
positioning the nose
into the
recess.
(b) Pay attention to the
.
guiding keyway
6. Insert the 240V heater power connector into the heater power receptacle. Turn the 240V heater power
connector to clockwise until it snaps in place.
®
© BriskHeat
Corporation. All rights reserved.
SDCE Digital Benchtop Temperature Controller
2
b
1
L1
a
b
2
8
a
L2

Publicité