7. Life phases
7.3.2 Connection of the drive and hand switch
The mains plug must not be plugged in.
Insert the hand switch connector 2.
Insert the drive connector 1.
Insert the mains plug.
You are now able to operate the drive.
7.3.3 Switching the mains voltage 115 V/230 V
The mains plug has to be removed before switching the voltage selector switch. The
controller may only be connected to the mains voltage that has been selected on this
switch.
7.3.4 Pin assignment of the hand switch socket (centre socket)
24 Vdc
1
4
Drive 1
drive in
Drive 1
drive out
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Potential-free
contacts
On controller versions with only one drive connection, pins 3 and 5 have no function.
When controlling using another operating unit than the RK hand switch, take care
that the control contacts are open when in the idle state (the drives do not move). The
duty cycle must be observed when operating the controller, even if the drive des not
move.
The transformer controller will be destroyed when operated continuously.
28
ground
Drive 2
3
drive out
5
Drive 2
2
drive in
24 Vdc
Drive 1 drive out
Drive 2 drive out
Drive 1 drive in
Drive 2 drive in