Télécharger Imprimer la page

Publicité

Liens rapides

05/18 IL03801009Z
T5B..., T5...
T5(B).../E
T5(B).../Z
T5B.../I4
T5.../I5
Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
T5(B).../EA/SVB
T5(B).../V/SVB
T5B.../I4/SVB
T5.../I5/SVB
Instruction Leaflet
Montageanweisung
Notice d'installation
Instrucciones de montaje
Istruzioni per il montaggio
安 安 装说明
装说明
Инструкция по монтажу
Electric current! Danger to life!
en
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
de
Nur Elektrofachkräfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
fr
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
es
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
it
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
zh
触电危险!
触电危险!
只允许专业人员和受过专业训练的人员进行
下列工作。
Электрический ток! Опасно для жизни!
ru
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
a
T5B
13 mm (0.51")
T5
13 mm (0.51")
UV-P3
15 mm (0.59")
K-CI-K4
15 mm (0.59")
K-CI-K5
16 mm (0.63")
T5B..., T5...
2
1 x 1.5 - 25 mm
2
2 x 1.5 - 10 mm
2
1 x 2.5 - 35 mm
2
2 x 2.5 - 16 mm
UL-File: E36 332
UL
AWG 12/4
UL/CSA:
Suitable For Use As Motor Branch
Circuit Disconnecting Means With
Suffix SVB.
Break All Lines.
Short Circuit Withstand
10 kA RMS SYM 600 V AC
Max Fuse
T5B... – 100 Class J
T5... – 100 Class J
Standard Short Circuit
5 kA RMS SYM 600 V AC
Max Fuse
T5B... – 100 A
T5... – 100 A
Switch or enclosure must be
padlockable if used as a Motor
Branch Circuit Disconnector means.
tightening
torque
4 Nm
(35.5 lb-in)
1/4

Publicité

loading

Sommaire des Matières pour Eaton T5B Serie

  • Page 1 T5B… – 100 A T5… – 100 A Switch or enclosure must be padlockable if used as a Motor Branch Circuit Disconnector means. T5…/I5 T5…/I5/SVB Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
  • Page 2 4 x ST 3.9 x 19 1 Nm (8.85 lb-in) Fig. 3 4 x ST 3.9 x 19 1 Nm (8.85 lb-in) 1 Nm (8.85 lb-in) 1 Nm (8.85 lb-in) Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
  • Page 3 (8.85 lb-in) (8.85 lb-in) [mm] T5B-1(2) T5B-3(4) T5-1(2) T5-3(4) [in] T5B-1(2) T5B-3(4) T5-1(2) T5-3(4) 6.29 6.29 7.87 7.87 9.45 9.45 11.02 11.02 3.74 6.29 4.92 6.29 Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
  • Page 4 包括 содержится 5 - 5.5 mm (0.2 - 0.22”) Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en) Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany © 1999 by Eaton Industries GmbH, Eaton.eu/documentation Eaton.com/recycling...

Ce manuel est également adapté pour:

T5 serie