Fault
Appliance cannot be started
Insufficient water quantity
Insufficient cleaning result
Brushes do not turn
Appliance vibrates.
Power
Nominal voltage
Average power consumption
Brush engine output
Maximum allowed net impedance
Type of protection
Working width
Brush diameter
Brush speed
Dimensions and weights
Theoretical surface cleaning performance
Volume, fresh water reservoir
Length (without pushing handle)
Width
Height (without pushing handle)
Weight (without tank content, without brushes)
Values determined as per EN 60335-2-67
Vibration total value on arms
Uncertainty K
Sound pressure level L
pA
Uncertainty K
pA
Faults
Remedy
Check if the mains plug is connected.
Socket fuse rating too low, look for proper socket.
Check fresh water level, refill tank if necessary.
Clean the ball valve in the fresh water reservoir.
Check and ensure that the fresh water reservoir is seated properly on the appliance.
Filter in the fresh water reservoir is plugged, clean filter.
Pull out the water distribution bars above the brushes and flush with water.
Check hoses for blockages; clean if required.
Check the brushes for wear, replace if required.
Use brush rollers suited for the type of dirt and floor covering.
Check if foreign matters block the brushes; remove foreign matter if required.
Overcurrent protective switch was triggered. The overcurrent protective switch will allow the op-
eration after max. one minute.
Brush rollers are out of balance, replace the brush rollers.
Specifications
EN
V/Hz
W
W
Ohm
mm
mm
1/min
m²/h
l
mm
mm
mm
kg
m/s
2
m/s
2
dB(A)
dB(A)
5
-
1.783-320.0
1.783-321.0
1.783-320.0
220...240 / 1~50
230 / 1~60
1300
2100
0.396+j0.248
IPX4
400
96
1100
400
10
490
460
250
38
<2,5
0,2
73
1
13