Maintenance And Cleaning; Guarantee Conditions - Pontec PondoMatic Notice D'emploi

Masquer les pouces Voir aussi pour PondoMatic:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- EN -
Remedy of faults
Malfunction
The unit does not perform its suction function
The unit does not reach its full capacity
The collection container does not run empty,
the unit does not prime
Low suction capacity
Wear parts
Filters and valve rubber elements are wear parts and are not covered by our warranty.

Maintenance and cleaning

How to proceed:
 D
Switch off the unit and disconnect the power plug.
Disconnect the hoses.
Undo the side locking clips and remove the motor housing.
Undo the filter holder.
Remove the filter and rinse under running water.
– If the filter is damaged, replace it with an original filter.
Clean the container.
Clean the bottom of the motor housing.
Check the rubber valve in the drain hose and clean.
Reassemble the unit in the reverse order.
Storage/overwintering
Empty out the collection container and clean the unit. Store in a dry, frost protected room, inaccessible to children.
Disposal
Note
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided
for this purpose.

Guarantee conditions

PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer's claims against the dealer.
12
Cause
Drain hose incorrectly fitted
Excessive height difference between water
level and unit
Dirt has accumulated in the foam filter, in the
suction tube or in the suction hose
Dirt has accumulated in the area of the non-re-
turn valve at the drain hose preventing it from
closing properly
The collection container cannot drain
Collection container and drain hose are soiled
The more tubes are used, the higher the tube
frictional resistance. The suction capacity
reduces.
Remedy
The non-return valve must be located at the
free end of the drain hose
Places the unit at water level height
Remove soiling
Remove soiling
Lay the drain hose without kinks.
Provide slight gravity for the drain hose.
After draining, almost no water should remain
in the collection container.
Remove soiling
Hold the suction hose as flat as possible to im-
prove the suction performance

Publicité

Table des Matières
loading

Table des Matières