Initial Operation; Warning Instructions - Weller WHP 50 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Preheating plate WHP.50 / WHP 80
1. Description
The preheating plate WHP 50 / WHP 80 has been designed for connection to the
following controlled soldering / desoldering stations:
WHP 50: all 50W and 80W power units with minimum setting temperature 50°C.
WHP 80: all 80W power units with minimum setting temperature 50°C.
The heating plate has a heated surface of 80 x 50mm, which is heated steadily from
connected, the plate temperature can be continuously.electronically adjusted. The
connecting cable is made of temperature-resistant silicone material. Components to
be preheated can be attached by means of holding clamps, if necessary.
Mains voltage:
Power consumption WHP 50
WHP 80:
Operating temperature:
Heated surface:
Dimensions of special steel receptacle:

2. Initial operation

Connect and secure the connector plug of the preheating plate to the connector socket
on the control unit to the requested temperature. Operating temperature: 50" to 200°C.
3. Potential balance
By means of equipotential balancing conductor, the preheating plate is connected to
for heating. By means of the control unit
used
24V
50W
80W
50" to 200°C
80 x 50mm
150 x 120 x 45mm
the control unit, The equipotential bonding can be adjusted according to the data in
the operating instructions of the control unit.
4. Instructions for use
During the preheating process of ceramic base material, it is advisable to use a thin
Teflon respectively Kapton intermediate plate on the heating plate in order not to
return the heat required for soldering to the heating plate.
Information contained in the operation manuals of any other connected WELLER
tools should be observed in addition to the information contained
manual.
5. Scope of delivery
Preheating plate
Operating instructions

6. Warning instructions

Do not place any inflammable objects on the heating plate.
Danger of burn!
The permissible table heating must not be exceeded during
installation or add-on.
Use Weller units which are suitable for connection only.
in this operation