Caution; Description; Initial Operation; Scope Of Delivery - Weller WHP 80 Mode D'emploi

Masquer les pouces Voir aussi pour WHP 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
English
Thank you for placing your trust in our company by purcha-
sing the Weller preheating plate WHP 80. Production was
based on stringent quality requirements which guarantee the
perfect operation of the device.

1. Caution!

Please read these Operating Instructions and the attached
Safety Information carefully prior to initial operation. Failure
to observe the safety regulations results in a risk to life and
limb.
The manufacturer shall not be liable for damage resulting
from misuse of the machine or unauthorised alterations.
Safety Informations
● Always place the soldering iron in the original holder.
● Remove all inflammable objects from the proximity of the
hot soldering tool.
● Use suitable protective clothing. Risk of burns from liquid
solder.
● Never leave the hot soldering iron unsupervised.
● Never work on voltage-carrying parts.
● Please read the safety instructions for the supply unit
used.

2. Description

The preheating plate WHP 80 has been designed for
connection to the following controlled soldering / desoldering
stations:
WHP 80:
all 80 W power units with minimum setting tem-
perature 50°C.
The heating plate has a heated surface of 80 x 50 mm, which
is heated steadily from 50°C to 200°C. Protective low volta-
ge is used for heating. By means of the control unit connec-
ted, the plate temperature can be continuously electronically
adjusted. The connecting cable is made of temperature-resi-
stant silicone material. Components to be preheated can be
attached by means of holding clamps, if necessary.
Technical Data
Mains voltage:
Power consumption WHP 80:
Operating temperature:
Heated surface:
Dimensions of special steel
receptacle:
5
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
24 V
80 W
50°C to 200°C
80 x 50 mm
150 x 120 x 45 mm

3. Initial operation

Connect and secure the connector plug of the preheating
plate to the connector socket on the control unit to the
requested temperature.
Operating temperature: 50°C to 200°C.
4. Potential balance
By means of equipotential balancing conductor, the prehea-
ting plate is connected to the control unit. The equipotential
bonding can be adjusted according to the data in the opera-
ting instructions of the control unit.
5. Instructions for use
During the preheating process of ceramic base material, it is
advisable to use a thin Teflon respectively Kapton intermedia-
te plate on the heating plate in order not to return the heat
required for soldering to the heating plate.

6. Scope of delivery

Preheating plate
Operating instructions
Sous réserve de modifications techniques!
See the updated operating instructions at www.weller.eu.

Publicité